Air conditioning operating cost

System size, efficiency rating and compressor run time decide what cooling costs. Enter yours to get the number for a cooling hour, a month and a full season.

Your inputs

tons

One ton moves 12,000 BTU per hour. A typical central system is 2–4 tons; a window unit is about 0.5–1 ton.

SEER

On the yellow EnergyGuide label. New central units are usually 14–20 SEER; older ones 10–13. Do not treat SEER and SEER2 as interchangeable.

h/day

Not the hours the thermostat is on. Count the hours the outdoor unit is actually running, or take 50–75% of the time you leave cooling on.

days
$/kWh

Your rate is set to 17.0¢/kWh and is shared with the other calculators on this device.

Monthly cooling cost

$73.44

432 kWh at 17.0¢/kWh · 30 days

Approximate seasonal-equivalent draw
2,400 W
Cost per cooling hour
$0.41
Cost per day
$2.45
4-month cooling season
$293.76
Heat moved per hour
36 kBtu

Cost over time

Cost
1 month1 year$0$250$500$750$1,000

One billing period, then twelve months at this cooling usage and rate.

SEER mode is a rough seasonal-equivalent estimate, not a measured operating wattage. Known-watts mode uses the draw you supply. Both assume unchanged run time and rates; the season is four identical months.

Made on your device. It shows the result above and nothing else.

The link includes your inputs and electricity rate. Anyone with the link can view them.

Lower your electricity use

Tips and Tricks

Practical changes that move the number above, starting with the ones that usually save the most. The filled bars show how large a saving each tip usually delivers.

3–5% per °F

High saving01

Raise the setpoint and leave it alone

Cooling energy falls by roughly 3% for each degree Fahrenheit you raise the thermostat. Four degrees higher while the house is empty is the cheapest saving on this page, and it needs no equipment. A steady setting beats constant fiddling.

5–15% of draw

Moderate saving02

Change the filter, and clear the outdoor coil

A loaded filter or a dirty condenser coil restricts airflow and pushes compressor draw up by 5–15%, sometimes more on hot afternoons. Check the filter monthly through cooling season and rinse the outdoor unit once a year. It is the highest-return five minutes in home maintenance.

300–500 W

Small saving03

Set the blower fan to auto, not on

A continuously running air-handler blower adds 300–500 W around the clock and re-evaporates moisture the compressor just removed, so the house feels clammy at the same temperature. Use auto, or a thermostat circulate mode that runs the fan in short bursts instead.

The formula

Exactly what this page calculates

watts = (tons × 12,000 BTU/h) ÷ SEER
kWh    = (watts ÷ 1000) × run hours × days
cost   = kWh × rate

One ton of cooling equals 12,000 BTU per hour. In known-watts mode, the entered running draw replaces the SEER approximation. Do not substitute SEER2 or a window-unit CEER as though the rating were identical to SEER.

Assumptions and limits

What this model cannot know

  • Efficiency is treated as steady-state at the rated SEER, which understates the penalty of very hot afternoons and short cycling.
  • Hours per day means compressor run time, not the time the thermostat is set to cool.
  • Duct losses, window solar gain, infiltration, ceiling height and thermostat setbacks are not modelled.
  • For window and portable units, use known running watts rather than entering EER or CEER in the SEER field.

In detail

How to read your result

An air conditioner’s electrical draw is not the same as its cooling capacity. A 3-ton system moves 36,000 BTU of heat per hour, but the electricity it needs to do that depends on its efficiency: dividing that capacity by SEER 15 gives a rough seasonal-equivalent 2,400 W, not an actual measured operating draw.

SEER is a seasonal average rather than a single operating point, so this calculation is a rough approximation, not a measurement. Real draw varies with outdoor temperature, indoor humidity, thermostat setpoint and airflow. A clogged filter or a system low on refrigerant can add 5–15% on its own.

Run time is the input people underestimate most. A system switched on for eight hours in mild weather might only run its compressor for three. Measure it, or start from 50–75% of the hours you leave cooling on and adjust from there.

Questions about this calculation

Is a heat pump different from a central air conditioner?

Both can cool a home using a compressor and refrigerant. A heat pump also reverses the refrigeration cycle to provide heating, while a cooling-only central air conditioner needs a separate heating system. This calculator estimates cooling electricity usage; it does not estimate winter heat-pump efficiency or electric auxiliary heat.

Why does my heat-pump thermostat say AUX HEAT?

For many heat pumps, AUX HEAT indicates supplemental electric-resistance heating. It may turn on during very cold weather, defrost or rapid temperature recovery. Because resistance heat typically consumes more electricity to provide the same warmth, avoiding unnecessary auxiliary operation can matter. A sudden large thermostat increase can trigger it on some systems, but the behavior depends on your equipment and thermostat controls.

How much does it cost to run air conditioning for 8 hours?

Using an illustrative 2,400 W running draw, eight active hours uses 19.2 kWh and costs $3.26 at 17 cents/kWh. A SEER-based approximation is not a measurement of actual draw. Use the known-watts mode when suitable equipment data is available.

Is 15 SEER good?

Compare ratings measured under the same test procedure. SEER and SEER2 are not interchangeable. A change from SEER 14 to SEER 18 corresponds to roughly 22% less seasonal energy for the same modeled cooling load, but actual savings depend on installation and operation.

Does raising the thermostat save money?

Yes. Cooling energy typically falls by about 3% for each degree Fahrenheit you raise the setpoint, with a common range of 3–5% per degree depending on climate. Raising it 4°F while the house is empty is one of the cheapest savings available.

Do the blower and dehumidifier count?

Use whole-system power in known-watts mode where available. Do not add blower power again if it is already included in your measurement or equipment rating. A separate dehumidifier is an additional load. Seasonal efficiency ratings have their own test boundaries.

Why was my summer bill so much higher than this?

Rate tiers, time-of-use windows, an unusually hot month and other appliances all compound. Compare the kWh on your statement with the estimate here first; if the kilowatt-hours match but the dollars do not, the difference is in the rate structure.