An air conditioner’s electrical draw is not the same as its cooling capacity. A 3-ton system moves 36,000 BTU of heat per hour, but the electricity it needs to do that depends on its efficiency: dividing that capacity by SEER 15 gives a rough seasonal-equivalent 2,400 W, not an actual measured operating draw.
SEER is a seasonal average rather than a single operating point, so this calculation is a rough approximation, not a measurement. Real draw varies with outdoor temperature, indoor humidity, thermostat setpoint and airflow. A clogged filter or a system low on refrigerant can add 5–15% on its own.
Run time is the input people underestimate most. A system switched on for eight hours in mild weather might only run its compressor for three. Measure it, or start from 50–75% of the hours you leave cooling on and adjust from there.
Is a heat pump different from a central air conditioner?+
Both can cool a home using a compressor and refrigerant. A heat pump also reverses the refrigeration cycle to provide heating, while a cooling-only central air conditioner needs a separate heating system. This calculator estimates cooling electricity usage; it does not estimate winter heat-pump efficiency or electric auxiliary heat.
Why does my heat-pump thermostat say AUX HEAT?+
For many heat pumps, AUX HEAT indicates supplemental electric-resistance heating. It may turn on during very cold weather, defrost or rapid temperature recovery. Because resistance heat typically consumes more electricity to provide the same warmth, avoiding unnecessary auxiliary operation can matter. A sudden large thermostat increase can trigger it on some systems, but the behavior depends on your equipment and thermostat controls.
How much does it cost to run air conditioning for 8 hours?+
Using an illustrative 2,400 W running draw, eight active hours uses 19.2 kWh and costs $3.26 at 17 cents/kWh. A SEER-based approximation is not a measurement of actual draw. Use the known-watts mode when suitable equipment data is available.
Is 15 SEER good?+
Compare ratings measured under the same test procedure. SEER and SEER2 are not interchangeable. A change from SEER 14 to SEER 18 corresponds to roughly 22% less seasonal energy for the same modeled cooling load, but actual savings depend on installation and operation.
Does raising the thermostat save money?+
Yes. Cooling energy typically falls by about 3% for each degree Fahrenheit you raise the setpoint, with a common range of 3–5% per degree depending on climate. Raising it 4°F while the house is empty is one of the cheapest savings available.
Do the blower and dehumidifier count?+
Use whole-system power in known-watts mode where available. Do not add blower power again if it is already included in your measurement or equipment rating. A separate dehumidifier is an additional load. Seasonal efficiency ratings have their own test boundaries.
Why was my summer bill so much higher than this?+
Rate tiers, time-of-use windows, an unusually hot month and other appliances all compound. Compare the kWh on your statement with the estimate here first; if the kilowatt-hours match but the dollars do not, the difference is in the rate structure.