Estimate the cost of electric heat strips from their kW rating and actual run time.
Your inputs
kW
h/day
days
$/kWh
Exclude fixed fees when estimating appliance savings.
Use your own tariff and equipment figures. All defaults are examples.
Estimated strip-heat cost
$102.00
Electricity for the period
600.0 kWh
Cost per active hour
$1.70
This estimates electric resistance strips only. It excludes the heat-pump compressor and blower unless their power is explicitly included. Auxiliary heat can be normal in cold weather or defrost. Persistent unexpected operation needs an HVAC check.
Made on your device. It shows the result above and nothing else.
The link includes your inputs and electricity rate. Anyone with the link can view them.
Practical changes that move the number above, starting with the ones that usually save the most. The filled bars show how large a saving each tip usually delivers.
Find the cause
High saving01
Find out why the strips switched on
Auxiliary heat usually does one of three jobs: defrosting the outdoor coil, recovering from a setpoint change, or covering heat the heat pump cannot deliver at the current outdoor temperature. A thermostat that reports run time by stage shows which one is happening before you change anything.
A few °F at a time
Moderate saving02
Avoid large setbacks as a warm-up trick
Recovery after a big setback is the most common reason strips run for hours in mild weather. Smaller steps, or a schedule that starts earlier, let the heat pump recover on its own instead of calling for resistance heat.
Worth a service call
Small saving03
Confirm the strips are off when it is mild
Strip heat running on a 50°F afternoon means the thermostat or the system is misconfigured. That is a diagnostic question for an HVAC technician, not a habit you can fix with the settings on this page.
The formula
Exactly what this page calculates
kWh = strip kW × active hours/day × days
cost = kWh × electricity rate
Example: 10 kW of strips running 2 hours/day for 30 days uses 600 kWh, costing $102 at $0.17/kWh.
Assumptions and limits
What this model cannot know
This estimates electric resistance strips only. It excludes the heat-pump compressor and blower unless their power is explicitly included. Auxiliary heat can be normal in cold weather or defrost. Persistent unexpected operation needs an HVAC check.
Illustrative inputs are not a quote, diagnosis or prediction of future prices.
In detail
How to read your result
Example: 10 kW of strips running 2 hours/day for 30 days uses 600 kWh, costing $102 at $0.17/kWh.
This estimates electric resistance strips only. It excludes the heat-pump compressor and blower unless their power is explicitly included. Auxiliary heat can be normal in cold weather or defrost. Persistent unexpected operation needs an HVAC check.
Questions about this calculation
Does this include my entire electric bill?+